gated/v6 compatibility issues.
Robert Rockell
Robert Rockell <rrockell@sprint.net>
Fri, 9 Oct 1998 12:26:56 -0400 (EDT)
Has anyone ever run into any compatibility issues between gated and cisco 0519 code?
Gated side is seeing problems with optional attributes, but I am only sending AS_PATH
info. On the cisoc side, debug only show session go into open-active state, and then
reset, without any icmp information. Any insight woudl be appreciated. error log from
Gated below:
Oct 9 18:30:00 6bone gated[78]: NOTIFICATION received from 3ffe:2900:a:b::1 (External AS
6175): code 3 (Update Message Error) subcode 1 (invalid attribute list) data 00 02 01 10
3f
fe
Oct 9 18:31:05 6bone gated[78]: bgp4+_recv_reach: peer 3ffe:2900:a:b::1 (External AS
6175)
attribute too short (2 < 6207)
Oct 9 18:31:05 6bone gated[78]: NOTIFICATION sent to 3ffe:2900:a:b::1 (External AS
6175):
code 3 (Update Message Error) subcode 9 (error with optional attribute) data
this is a tunnel interface, which I don't believe should make any difference.
With BGP4+, are attributes mapped in the same way as bgp4 (v4)? there don't appear to be
any optional attributes being passed.
Thanks
Rob Rockell
Sprintlink Internet Service Center
Operations Engineering
703-689-6322
1-800-724-3329, PIN 385-8833