gated/v6 compatibility issues.

Robert Rockell Robert Rockell <rrockell@sprint.net>
Fri, 9 Oct 1998 12:26:56 -0400 (EDT)


Has anyone ever run into any compatibility issues between gated and cisco 0519 code?
Gated side is seeing problems with optional attributes, but I am only sending AS_PATH
info.  On the cisoc side, debug only show session go into open-active state, and then
reset, without any icmp information. Any insight woudl be appreciated. error log from
Gated below:


Oct  9 18:30:00 6bone gated[78]: NOTIFICATION received from 3ffe:2900:a:b::1 (External AS

6175): code 3 (Update Message Error) subcode 1 (invalid attribute list) data 00 02 01 10
3f 
fe

Oct  9 18:31:05 6bone gated[78]: bgp4+_recv_reach: peer 3ffe:2900:a:b::1 (External AS
6175) 
attribute too short (2 < 6207)
Oct  9 18:31:05 6bone gated[78]: NOTIFICATION sent to 3ffe:2900:a:b::1 (External AS
6175): 
code 3 (Update Message Error) subcode 9 (error with optional attribute) data

this is a tunnel interface, which I don't believe should make any difference.





With BGP4+, are attributes mapped in the same way as bgp4 (v4)? there don't appear to be
any optional attributes being passed.




Thanks
Rob Rockell
Sprintlink Internet Service Center
Operations Engineering
703-689-6322
1-800-724-3329, PIN 385-8833